    Add After=time-sync.target to systemd unit file · 3a50d899
    Guillem Jover authored
    If the WAL is replayed with the wrong time set, the TSDB will end in
    a broken state, and prometheus will fail to ingest samples for a long
    while due to the new samples appearing to be out-of-order.
    
    Closes: #981110
    Thanks-to: Marco d'Itri <md@linux.it>